Validation data of the Korean Healthcare-associated Infections Surveillance System (KONIS) intensive care unit module between 2008 and 2017
Sensitivity (%) | Specificity (%) | Positive predictive value (%) | Negative predictive value (%) | |
---|---|---|---|---|
Urinary tract infections | ||||
KONIS 2008 | 92.5 | 100 | 100 | 98.0 |
KONIS 2010 | 88.4 | 97.9 | 88.5 | 97.7 |
KONIS 2014 | 85.3 | 98.7 | 85.3 | 98.7 |
KONIS 2017 | 72.0 | 99.3 | 90.0 | 97.5 |
Bloodstream infections | ||||
KONIS 2008 | 86.7 | 100 | 100 | 98.6 |
KONIS 2010 | 90.6 | 98.6 | 87.9 | 98.9 |
KONIS 2014 | 74.0 | 99.1 | 94.7 | 94.6 |
KONIS 2017 | 63.2 | 98.8 | 88.9 | 94.8 |
Pneumonia | ||||
KONIS 2008 | 71.4 | 98.6 | 78.9 | 97.9 |
KONIS 2010 | 55.6 | 99.3 | 71.4 | 98.7 |
KONIS 2012 | 91.7 | 100 | 100 | 97.7 |
KONIS 2014 | 66.7 | 98.7 | 78.3 | 97.7 |
KONIS 2017 | 70.6 | 99.6 | 92.3 | 98.2 |